Precision Colorimeters at an Affordable Price

Vteke colorimeters are designed for on-site measurement of various materials, offering one-button operation for quick pass/fail results.

Colorimeters C-200 series

Reliable color meter, precision dE*ab≤0.03. Ideal for plastics, coatings, printing, hardware, textiles, food, etc. Easy to use and highly cost-effective!

  • Enhanced repeatability accuracy with dual optical path design.
  • Measures over 30 metrics including color difference, whiteness, and yellowness.
  • Features 37 evaluation lighting options.
  • Capable of measuring fluorescent colors with UV inclusion.
  • Offers up to 6 measuring apertures for diverse sample requirements.
  • Integrated high-definition camera clearly displays testing area on the screen for confident testing.
  • Automatic calibration with a “synthetic diamond” on the base to ensure long-term instrument stability.
  • Compatible with Android and iOS mobile apps.
  • Equipped with a robust PC color management system.

Repeatability dE*ab ≤ 0.03.

The dual-pathway design allows simultaneous monitoring of the sample signal and the fluctuations in light source energy, thereby reducing interference during measurements and enhancing stability. This design has improved the instrument’s repeatability index to a level of dE*ab ≤ 0.03. The technology ensures the speed, accuracy, and consistency of measurements and is protected by invention patents in both China and the United States.

Over 30 measurement indicators

  • RGB, Lab, Spectral Reflectance, LCh, Hunter Lab, CIE-Luv, XYZ, Yxy
  • Color difference: ΔEab, ΔEcmc, ΔE94, ΔE00
  • Whiteness: ASTM E313-00, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby
  • Yellowness: ASTM D1925, ASTM E313-00, ASTM E313-73
  • Blackness: My,dM. Staining Fastness, Color Fastness, Tint (ASTM E313-00)
  • Color Density CMYK (A,T,E,M), Metamerism Index Milm, Munsell, Opacity, Strength (Dye Strength, Coloring Power).
Includes SCI measurement mode

SCI (Specular Component Included) measurement is primarily used in situations where the focus is on the properties of the color itself rather than the glossiness of the surface to which the color is applied. For example, in certain textile products, the accuracy of the color is extremely important, whereas the surface glossiness is not a primary consideration.

37 types of evaluation light sources

There are 37 types of evaluation light sources available, including A, B, C, D50, D55, D65, and more, covering nearly all color measurement standards and light source types used in the industry.

11mm, 6mm, 3mm apertures

We offer three apertures (11mm, 6mm, 3mm) to accommodate different sample requirements. Switching the measurement aperture is straightforward—just remove one and install another with a simple twist, no screws needed. Set the large aperture (Φ11mm) to ‘M’ and the smaller apertures (Φ6mm, Φ3mm) to ‘S’.

UV - for measuring fluorescent colors

Even when assessing colors on surfaces containing fluorescent materials, the C-200 series colorimeter consistently delivers reliable and precise reflectance data.

'artificial diamond' — calibration whiteboard

The calibration whiteboard is key to ensuring instruments’ accuracy. Made from zirconium with a Mohs hardness of 9, it is as hard as diamond, scratch-resistant, and doesn’t change color with temperature or humidity shifts. This makes it more stable and durable than similar products using ceramic or plastic.

The whiteboard is installed on a calibration base. Just place the colorimeter on the base for it to automatically calibrate, ensuring it’s always ready and stable.

 
Connect your smartphone and computer

Our apps are available for both iOS and Android, allow you to create a personal color database. You can log details of various color cards, search for similar colors, and upload and share data. The package also comes with the ColorExpert color management system, which can be connected to your computer via Bluetooth or USB. It features four key functions: My Colors, Color Measurement, Color Matching System (available for purchase), and Personal Center.

Testimonials

经过多家对比,最终选择vteke测色仪,专业且准确。同样的价格,vteke C-210可以测量30多种参数,有30多种光源,性价比很高,值得够买。

5/5

Mr. Christian

测试不同批次的水洗色牢度,找到了vteke测色仪。他们给了我们很多专业的建议及详细的技术科普,对我们的帮助非常大!

5/5

Shelly Barns

发货速度很快,产品包装精美,操作简单易懂,测量的结果基本没有误差,价格不贵,强烈推荐给大家。

5/5

Jacob Luke

Specifications

ModelColorimeter C-200

Colorimeter C-210

Most recommended

Colorimeter C-220
Geometryd/8, SCI
RepeatabilityΔE*ab ≤ 0.03
Display Precision0.01
Illumination Area/Apertures2 Apertures:
Φ6mm,
▽6mm,
4 Apertures:
Φ11mm,Φ6mm,
▽11mm,▽6mm,
6 Apertures:
Φ11mm,Φ6mm,Φ3mm,
▽11mm,▽6mm,▽3mm,
Color Spaces and IndicesReflectance, CIE-Lab, CIE-LCh, HunterLab, CIE Luv, XYZ, Yxy, RGB, Color difference(ΔE*ab, ΔE*cmc, ΔE*94,ΔE*00),WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger Stensby), YI(ASTM D1925,ASTM E313-00,ASTM E313-73), Blackness(My, dM),Color Fastness, Tint,(ASTM E313-00),Color Density CMYK(A,T,E,M), Milm, Munsell, Opacity, Color strength
IlluminantsA, B, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, U35, DLF, NBF, TL83, TL84, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2.
 Field of view2°, 10°
Sphere Size40mm
StandardsConform to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7
Spectroscopic methodNanointegrated spectroscopic devices
SensorSilicon photodiode array, Double 16 groups.
Wavelength Interval10nm
Wavelength Range0-200%
Reflectance Resolution0.01%
Measurement Time≈ 1 seconds
Light SourceFull wavelength balanced LEDFull wavelength balanced LED + UV
Measurement observationVisual inspectionCamera
CalibrationManual CalibrationIntelligent auto calibration
SoftwareAndroid, iOS, Windows
InterfaceUSB, Bluetooth
ScreenIPS Full Color Screen, 2.4 inches
BatteryLi-ion, rechargeable, 8000 times continuous tests, 3.7V/3000mAh
Lamp Lifetime10 years, 1 million tests
LanguagesChinese and English
Storage MemoryInstrument: 100 standard samples, 10,000 test samples; APP: Massive storage.
  • Diffuse illumination with D/8° directional reception, including/excluding specular reflection.
  • Standard deviation of measuring a whiteboard 30 times with 5-second intervals after whiteboard calibration.

Ask For A Quick Quote

We will contact you within 1 working day, please pay attention to the email with the suffix “@vteke.com